Nanoflex® Optical Reflector
Effective Green Lighting Solution
About Nanoflex® Optical Reflector
Nanoflex® Optical Reflector is designed to cater to the energy needs of end users and is used for energy-efficient lighting retrofits for premises, which enables energy cost savings whilst still fulfulling the required luminous standards.
The optical coating on Nanoflex® provides ideal diffusive and reflective surface to capture light rays from any light source including fluorescent lamps to enhance illumination and the product is best for energy saving through de-lamping exercise. This de-lamping exercise is recommended by Association of Energy Engineers (AEE), U.S.A and Electrical and Mechanical Services Department, Hong Kong.
Benefits of using Nanoflex® Optical Reflector:
- Cost effective and reduce lighting energy consumption by up to 50%
- Can be used with existing luminaire without the need for further capital expenditure
- Capture light loss from design limitation of luminaire and efficiently reflect back to workspace
- Enhance existing fluorescent tube light source by up to 40%
- Up to 10 years of performance consistency
- Enhance luminance in climate control environment without increasing heat source from electrical parts and further reduce air-conditioning load to enhance energy savings
- Safe and simple installation, minimal maintenance required
- Perfectly complements the lighting sources such as T5 and T8 fluorescent lamps, which are commonly applied in commercial buildings and office, industrial building and factories, hotels, government buildings and schools, hospitals and healthcare centres
How does Nanoflex® Optical Reflector enhance diffuse reflectance?

How does Nanoflex® Optical Reflector save energy?

- Nanoflex® has direct reflectance of 95% while the distinguished diffuse reflectance is 95% invisible wavelength.
- Nanoflex® is heated resistant up to 400°C and does not contain hazardous substance
- Nanoflex® has been tested for its durability, safety, eco-friendliness and photometric performance.
Applications on Fluorescent tubes
![]() |
![]() |
| Before Installation (Single line lighting arrangement) | After Installation (50% De-lamped) |
Annual lighting energy savings (kWh) can be up to 50% while fulfilling the lighting quality standard
Accreditations
Passed BS Fire Safety Test (BS 476 Part 6 & 7)- Passed UV Aging Test
- Passed Lambertian Spectra Reflection Test
- RoHS Qualified
- Granted “Green Label” product by Green Council in Hong Kong